For homeowners + builders

Resources.

How-to pages, installation guides, specs, performance reports, and other documents in one library. Looking for construction photos? Visit the Gallery.

How to build

Task pages and the interactive build, gathered from the installation library and the homepage.

Web page

Installation and Field Support Hub

Panel setup, openings, electrical chases, blocking, tools, and field guidance in one library.

Approved and sealed project documents control.

Interactive

Interactive step-by-step build

Watch a narrated or quick build of a ThermaTech house.

Interactive

Full-house interactive model

See how the panels set, align, and connect in the house model.

Web page

Set + brace

Follow the written checks and interactive lessons for setting, aligning, fastening and bracing your panel package.

Web page

Bottom plate

A direct training page for plate layout, anchorage, tolerances, and the checks that happen before the first panel is set.

Web page

Alter a panel

The system can accommodate documented resizing and rejoining methods when the approved project documents allow the change.

Web page

Bucks + headers

Keep openings coordinated with the shop drawings, approved load path, flashing strategy, and the selected window or door package.

Web page

Electrical

A direct field page for using the horizontal chases while protecting the panel, required clearances, and approved structural conditions.

Web page

Blocking + connections

Plan attachment points for cabinets, fixtures, finishes, and intersecting walls before the assembly is closed.

Installation guides

The current field PDFs. Approved project drawings and engineered details remain in control.

PDF · 6.5 MB

IFP Panel Installation Guide

The current IFP installation guide.

PDF · 9.4 MB

IHP Panel Installation Guide

The current shared IHP installation guide. Project details distinguish Wood / Wood and Wood / Metal.

The planned system-specific booklet with linked contents will be added after approval.

PDF · 4.0 MB

Header and buck assembly

Field sequence for headers, window bucks, and door bucks.

PDF · 2.0 MB

Panel modifications

Documented resizing and rejoining methods when the approved documents allow the change.

PDF · 3.9 MB

Electrical installation

Routing wire and setting boxes in the panel chases.

PDF · 1.6 MB

Wall blocking

Blocking and connection references for cabinets, fixtures, and intersecting walls.

Specs and details

Drawing files will be listed here when they are approved for publication.

DWG · not published

IFP drawing details

Awaiting approved drawing files. No public CAD download is available yet.

DWG · not published

IHP Wood / Wood drawing details

Awaiting approved drawing files. No public CAD download is available yet.

DWG · not published

IHP Wood / Metal drawing details

Awaiting approved drawing files. No public CAD download is available yet.

Performance

Reports and opinions, with the scope of each document kept attached.

PDF · 1.1 MB

TBS Wall Panel Thermal Performance Assessment

Effective assembly R-value modeling for two assessed 5.5-inch clear-wall configurations.

Not product certification. Air-leakage and infiltration inputs in the comparative analysis were assumed.

PDF · 3.8 MB

Fort Worth Residence Energy and Airtightness Story

Construction timing, owner-reported utilities, and a later whole-home blower-door result from one Fort Worth residence.

Single-home whole-building outcome. Project results vary.

PDF · 420 KB

Occupied-Home Indoor Air Quality Opinion

Mold-spore sampling in two occupied homes, with separate TVOC/TMVOC sampling in a third residence.

Small-sample professional opinion. This is not certification or causal proof.

PDF · 749 KB

IFP / IHP Alternative Material Review

Professional review of the systems under the alternative-material pathway.

Project-specific PE review and seal, plus acceptance by the local authority, are required.

Web page

How to read the thermal model

Plain-language reading of the Intertek assessment, with the modeled numbers and their limits.

Web page

How to read the indoor-air sampling

The occupied-home observations, the comparisons, and what those samples do not prove.

Web page

How to read the structural testing

The loading-rig photographs and the engineering pathway, kept separate.

Documents

Product references, the REZWOOD note, and the claims register.

PDF · 195 KB

Carpenter EPS evaluation

Surface-burning characteristics and conditions of use for the named Carpenter EPS insulation. Confirm the product specified for the project matches the document.

The separate Sierra/Carpenter UL listing and any additional product-specific documents will be added when supplied and verified. An evaluation report is not itself the separate UL Listing/Classification report, and neither establishes an hourly rating for a complete ThermaTech wall.

Document · not published

Foam-Plastic Protection Reference

A reference summary of thermal- and ignition-barrier provisions relevant to foam-plastic assemblies.

Not a fire certification, approval, or project-specific code analysis.

REZWOOD

Website · external file

REZWOOD protected lumber

REZWOOD is a protected-lumber brand specified for ThermaTech window and door buck frames, not a claim that the lumber is the redwood species.

Treatment documentation and approved details determine suitability. Moisture management remains essential.

Web page

Claims and supporting evidence

Each published statement, the source it rests on, and the limits that stay attached.